Place of Origin: | XIAN |
---|---|
Brand Name: | HCATM |
Model Number: | GMF701-K |
Minimum Order Quantity: | 1 |
Packaging Details: | Carton |
Delivery Time: | 3 to 7 working days after payment |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability: | PIECE/WEEK |
Working Environment Humidity: | ≦95% | Flow Rate Measurement Range: | 0-1 5m/s |
---|---|---|---|
Enclosure Rating: | IP68 | ||
High Light: | GPRS Electromagnetic Flow Meter,Battery Powered Electromagnetic Flow Meter,IP68 Electromagnetic Flow Meter |
Product Description
Electromagnetic flowmeter is an instrument that uses the principle of electromagnetic induction to measure the flow of conductive fluid based on the electromotive force induced when the conductive fluid passes through an external magnetic field.
Technical Parameters
Product name | Water meter electromagnetic flowmeter |
Working environment humidity | ≦95% |
Flow rate measurement range | 0-1 5m/s |
Applicable measuring diameter | DN10-DN2000 |
Measurement parameters | Instantaneous flow rate, instantaneous flow rate |
Detect alarm parameters | Fluid empty pipe detection alarm, excitation current detection alarm |
Communication method | RS485 (modbus protocol), GPRS |
Working temperature | -20°C-5 0°C |
Enclosure rating | IP68 |
Dielectric conductivity | Clean water>20 μ s/cm |
Matching accuracy grade | 0.5 level |
Record parameters | Cumulative total flow |
Calibration output signal | Pulse per unit volume flow |
Features
1. The measurement is not affected by changes in fluid density, viscosity, temperature, pressure and conductivity;
2. There are no obstructive flow parts in the measuring pipe, no pressure loss, and lower requirements for straight pipe sections. It has unique adaptability to slurry measurement;
3. Reasonably choose the sensor lining and electrode materials, that is, it has good corrosion resistance and abrasion resistance;
4. The converter adopts a novel excitation method with low power consumption, stable zero point and high accuracy. The flow range can reach 150:1;
5. The converter and the sensor can be integrated or separated;
6. The converter adopts 16-bit high-performance microprocessor, 2x16LCD display, convenient parameter setting and reliable programming;
7. The flowmeter is a two-way measurement system with three totalizers: forward total, reverse total and difference total; it can display positive and negative flow, and has multiple outputs: current, pulse, digital communication , HART;
8. The converter adopts surface mount technology (SMT), with self-check and self-diagnosis functions;
9. The measurement accuracy is not affected by changes in fluid density, viscosity, temperature, pressure and conductivity. The sensor induced voltage signal has a linear relationship with the average flow rate, so the measurement accuracy is high.
10. There are no obstructions in the measuring pipeline, so there is no additional pressure loss; there are no moving parts in the measuring pipeline, so the sensor has an extremely long life.
11. Since the induced voltage signal is formed in the entire magnetic field-filled space and is the average value on the pipe surface, the straight pipe section required by the sensor is shorter, and the length is 5 times the pipe diameter.
12. The converter adopts the latest and most advanced single-chip microcomputer (MCU) and surface mount technology (SMT) in the world, with reliable performance, high precision, low power consumption, stable zero point and convenient parameter setting. Click on the Chinese display LCD to display cumulative flow, instantaneous flow, flow rate, flow percentage, etc.
13. Two-way measuring system, which can measure forward flow and reverse flow. Special production technology and high-quality materials are used to ensure that the performance of the product remains stable for a long time.
Working Principle
The electromagnetic flowmeter is a flowmeter that performs flow measurement according to Faraday's law of electromagnetic induction. The advantage of the electromagnetic flowmeter is that the pressure loss is extremely small and the measurable flow range is large. The ratio of the maximum flow rate to the minimum flow rate is generally above 20:1. The applicable industrial pipe diameter range is wide, up to 3m. The output signal is linear with the measured flow rate, and the accuracy is high. It can measure the conductivity ≥5μs/cm Fluid flow of acid, alkali, salt solution, water, sewage, corrosive liquid and mud, mineral pulp, paper pulp, etc. But it cannot measure the flow of gas, steam and pure water.
Product Installation Drawing
Installation Precautions
1. For the convenience of installation, maintenance and maintenance, sufficient space should be reserved around the flowmeter
2. Avoid installing the flowmeter in a place where the temperature changes greatly or is subject to high temperature radiation from the equipment
3. The flowmeter should be installed indoors. If it is installed outdoors, it should be protected from direct sunlight. If necessary, install sun protection devices.
4. Avoid installing the flowmeter in an environment containing corrosive gas
5. Avoid installing the flowmeter in places with strong vibration sources and strong magnetic fields
7. Process tube requirements: 1. The inner diameter of the upstream and downstream process tubes and the inner diameter of the flowmeter should meet: 0.98DN≤D≤1.05DN
(DN: inner diameter of the flow meter; D: inner diameter of the process tube); 2. The process tube and the flow meter must be concentric, and the coaxial deviation should not be greater than 0.05DN