Leave a Message

We will call you back soon!

Your message must be between 20-3,000 characters!

Please check your E-mail!

SUBMIT

More information facilitates better communication.

Mr.
  • Mr.
  • Mrs.
OK

Submitted successfully!

We will call you back soon!

OK

Leave a Message

We will call you back soon!

Your message must be between 20-3,000 characters!

Please check your E-mail!

SUBMIT
Please leave your correct email and detailed requirements.
OK
China Pressure Transmitter manufacturer

From HCATM, Serve the world

English
  • English
  • French
  • German
  • Italian
  • Russian
  • Spanish
  • Portuguese
  • Dutch
  • Greek
  • Japanese
  • Korean
  • Arabic
  • Hindi
  • Turkish
  • Indonesian
  • Vietnamese
  • Thai
  • Bengali
  • Persian
  • Polish
Request A Quote
  • Home
  • Products
    • Pressure Transmitter
    • Electromagnetic Flow Meter
    • Vortex Flow Meter
    • Thermal Gas Mass Flow Meter
    • Turbine Flow Meter
    • Coriolis Mass Flow Meter
    • Ultrasonic Liquid Flow Meter
    • Oval Gear Flow Meter
    • Ultrasonic Level Transmitter
    • Radar Level Transmitter
    • Temperature Sensor
    • Load Cell Transmitter
    • Torque Measurement Sensor
    • SCADA Control System
    • Ultrasonic Doppler Flow Meter
    • Ultrasonic Flaw Detector
  • About Us
  • Factory Tour
  • Quality Control
  • Contact Us
Products
Home / Products / Radar Level Transmitter

24VDC 4~20 mA HART(four-wire system)RS485 Modbus Thread flange (optional) connection corrosive liquid radar level gauge

small.img.alt
small.img.alt 24VDC 4~20 mA HART(four-wire system)RS485 Modbus Thread flange (optional) connection	corrosive liquid radar level gauge 24VDC 4~20 mA HART(four-wire system)RS485 Modbus Thread flange (optional) connection	corrosive liquid radar level gauge small.img.alt 24VDC 4~20 mA HART(four-wire system)RS485 Modbus Thread flange (optional) connection	corrosive liquid radar level gauge 24VDC 4~20 mA HART(four-wire system)RS485 Modbus Thread flange (optional) connection	corrosive liquid radar level gauge small.img.alt 24VDC 4~20 mA HART(four-wire system)RS485 Modbus Thread flange (optional) connection	corrosive liquid radar level gauge 24VDC 4~20 mA HART(four-wire system)RS485 Modbus Thread flange (optional) connection	corrosive liquid radar level gauge
Basic Information
Place of Origin: Xi'an
Brand Name: HCATM
Certification: CE,RoHS
Model Number: GML801-A
Minimum Order Quantity: 1
Price: $300~1000USD/piece
Packaging Details: Packed in cardboard or wooden cases
Delivery Time: 3-5 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram,Paypal
Supply Ability: 100000 pieces per month
Get Best Price Contact Now Chat Now
  • Detail Information
  • Product Description
Medium: Liquid,Solid,Powder Range: 0~30m
Output: 4-20mA/HART/Modbus-RS485 Accuracy: ±3mm
Protection Level: IP67 Material: SS304,SS316
Process Connection: Flange;Thread Process Pressure: -0.1~4.0MPa
Medium Temperature: -40~+130℃;-40~+250℃ Antenna Material: Flexible Cable/316L/PTFE
High Light:

liquid level sensor

,

ultrasonic level sensor

Working Principle

High-frequency microwave pulse emitted by the guided wave radar propagates along the detecting component (wire cable or steel bar) and encounters the measured medium. Due to the sudden change of the dielectric constant, it causes reflection and a part of the pulse energy is reflected back. The time interval between the transmitted pulse and the reflected pulse is proportional to the distance of the measured medium.

GML801-A.jpg

Input

Guided wave radar is a measuring instrument based on the principle of time and travel. The radar wave runs at the speed of light, and the running time can be converted into a level signal by electronic components. The probe emits high frequency pulses and propagates along the cable or rod probe. When the pulse encounters the surface of the material, it is reflected back and received by the receiver in the meter, and the distance signal is converted into a level signal. The reflected pulse signal is transmitted along the cable or rod probe to the instrument electronics portion, and the microprocessor processes the signal to identify the echoes generated by the microwave pulses on the surface of the material.
The correct echo signal identification is done by the pulse software, and the distance D from the surface of the material is proportional to the time travel T of the pulse:
D=CxT/2, where C is the speed of light
Since the distance E of the empty can is known, the level L is: L=E-D

Output

By entering the empty tank height E (= zero point), full tank height F (= full scale) and some application parameters to set, the application parameters will automatically adapt the meter to the measurement environment, corresponding to the 4-20mA output.

 

Design Features

1.Guided wave radar level meter uses advanced microwave processing technology and unique Echo Di scovery echo processing technology, contact measurement, high measurement accuracy and more accurate measurement. At the same time, guided wave radar is anti-adhesive, and is not affected by the external environment such as medium temperature and adhesion.
2.A variety of process connection methods and types of detection components make the 70X series guided wave radar level gauges suitable for a variety of complex conditions and applications. Such as: high temperature, high pressure and small dielectric constant medium.
3.Using pulse working mode, the product has extremely low emission power, and can be installed in various metal and non-metal containers without harming human body and the environment.

Technical parameters

Applicable medium Liquid,solid,powder
Range 0~30m
Frequency 500MHz~1.8GHz
Antenna Flexible cable/304/PTFE
Precision ±1mm
Process temperature -40℃~+130℃
-40℃~250℃
Process pressure -0.1MPa~4.0MPa
Output 4~20mA/HART/RS-485 Modbus
Power supply 24VDC
Process connection Thread / flange (optional)
Explosion-proof grade ExdiaIICT6Gb

Dimensions

GML801-A.jpg

Electrical Connections

 

Power Supply

 

4~20 mA/HART (two-wire system):

Power supply and output current signals share a two-core shielded cable. See the technical data for the specific supply voltage range. For intrinsically safe type, a safety barrier must be added between the power supply and the meter.

4~20 mA/HART (four-wire system):

Power supply and the current signal are separated, and each uses a one-core two-core shielded wire. See the technical data for the specific supply voltage.

RS485/Modbus:

Power supply and Modbus signals are separated, and each uses a two-core shielded cable. See the technical data for the specific supply voltage range.

 

Connection Mode

GML801-A.jpg

 

Explosion-proof Connection

 

Explosion-proof version of this product is intrinsically safe. Explosion-proof mark: Exia IIC T6. The intrinsically safe guided wave radar level gauge is made of die-cast aluminum housing material, and the electronic components are sealed to ensure that sparks generated during partial circuit failure will not be released. This product is suitable for continuous measurement of the level of flammable medium below the Exia IIC T6 explosion-proof grade.
This product must be powered by a safety barrier. FBS-2 safety barrier is the associated equipment of this product, and the explosion-proof form is intrinsically safe. Explosion-proof mark: [Exia] IIC, supply voltage (21. 6~26.4) V DC, short-circuit current is 135mA, working current (4~20) mA.
Shielded cables are required for all cables, with a maximum length of 500m from the meter to the barrier. The distributed capacitance is ≤0.1uF/km and the distributed inductance is ≤1mH/km. The meter must be connected to the earth when it is installed. Do not use other associated equipment that has not been tested for explosion protection.

GML801-A.jpg

 

Installation Requirements

1.It is recommended to install at 1/4 or 1/6 of the diameter of the container. Note: The minimum distance from the tank wall is L0≥300mm, H0≥30mm.
2.Keep away from the inlet and outlet.
3.Keep away from obstacles such as limit switches, heating coils, and agitators. Note: The probe is ≥200mm away from obstacles.
4.When the container is a metal can, the radar should not touch the tank wall and the bottom of the tank over the entire range.
5.If the bottom of the container is tapered, the radar can be mounted in the center of the tank top.
The height of the installation short pipe should be L
1 ≤ 10cm.

 

GML801-A.jpg

 

Application

Power plants: coal piles, raw coal bunkers, fuel bunkers, cisterns, exhaust gas purification tanks, bunker pumps, steam drums, ash depots, fuel tanks, etc .;
Oil field: crude oil storage tank, refined oil storage tank, three-phase separator, sedimentation tank, sewage tank, oil-water interface, drilling mud tank, etc .;
Chemical industry: crude oil distillation tower, raw material silo, intermediate silo, reaction tank, ammonia water tank, solid silo, separator, asphalt storage tank, etc .;
Metallurgy: blast furnace, ore silo, ore crusher, raw material silo, auxiliary silo, alumina powder silo, electrolytic tank buffer tank, etc .;
Water conservancy: canals, reservoirs, farmland irrigation, river water level monitoring, flash flood warning, urban waterlogging, etc .;
Cement: stone silo, raw silo, cement silo, pulverized coal silo, slag storage silo, commercial boiler, etc .;
Food: Juice factory, milk factory, raw sugar storage tank, tomato sauce storage tank, brewery storage tank, etc .;
Pharmaceutical: Chinese medicine storage tanks, separators, fermentation tanks, etc .;
Water treatment: reservoirs, sewage tanks, water treatment tanks, sedimentation tanks, deep wells, drinking water networks, etc .;
Papermaking: raw material warehouse, storage tower, drying drum, chemical material storage warehouse, etc .;
Others: quarry, coal mine, environmental protection, shipbuilding and other industries.

GML801-B.jpg

Company Information

Xi 'an Huance Automation Technology Co., Ltd was founded in 2007. The company focuses on industrial pressure, flow, liquid level, temperature, weighing sensor production field. At present, it has provided tens of thousands of sensors and measurement and control systems for customers in petroleum, chemical industry, food processing, military industry and other industries. The company has passed the ISO9001 system certification, also through the SGS third party factory field certification. The company has more than 1000 square meters of independent production workshops, and a group of highly educated technical personnel focused on sensor technology research.

GML801-B.jpg

Certificates

_20200428180339.jpg

 

Packaging & Shipping

-3.jpg

 

 

Tag:

radar level meter,

liquid level transmitter,

load cell for weight measurement

Contact Details
Yang

WhatsApp : +8613227761772

More Radar Level Transmitter
  • Thread Flange 4MPa RS485 Radar Liquid Level Transmitter
    Show Details

    Thread Flange 4MPa RS485 Radar Liquid Level Transmitter

    Contact Now
  • 24VDC 4MPa 20mA HART RS485 Radar Level Transmitter
    Show Details

    24VDC 4MPa 20mA HART RS485 Radar Level Transmitter

    Contact Now
  • GML802-G Crystallization dew condensation corrosive liquid powder radar level transmitter
    Show Details

    GML802-G Crystallization dew condensation corrosive liquid powder radar level transmitter

    Contact Now
  • GML802-I 26GHZ 24VDC Flange sulfuric acid hydrochloric acid nitric acid PTFE radar level transmitter
    Show Details

    GML802-I 26GHZ 24VDC Flange sulfuric acid hydrochloric acid nitric acid PTFE radar level transmitter

    Contact Now
Categories
  • Pressure Transmitter
  • Electromagnetic Flow Meter
  • Vortex Flow Meter
  • Thermal Gas Mass Flow Meter
Factory Tour
  • Production Line
  • OEM/ODM
  • R&D
About Us
  • Introduction
  • History
  • Service
  • Our Team
Contact Us
Xi'an Huance Automation Technology Co., Ltd.
Room 11206, Unit 1, Building 2, Green Square, Jinye Road, Zhangba Street, Yantai District, Xi'an
86-029-68717668 Info@ultrasonicn.com
  • Privacy Policy
  • Sitemap
  • Mobile Site
China Good Quality Pressure Transmitter Supplier. © 2019 - 2022 pressureflowmeter.com . All Rights Reserved.